38 Switch Configuration
System process information
The ps command displays system process information to help you determine what processes are running
and central processing unit (CPU) usage.
The column titles in the following example are:
PID—Process identifier
PPID—Parent process identifier
%CPU—Percentage CPU usage
%MEM—Percentage memory usage
TIMEActual processing time
ELAPSED—Elapsed time since the process started
COMMAND—The command that initiated the process.
The following example displays current system processes.
SN6000 FC Switch #> ps
PID PPID %CPU %MEM TIME ELAPSED COMMAND
244 224 0.0 0.3 00:00:04 2-03:02:31 cns
245 224 0.0 0.3 00:00:06 2-03:02:31 ens
246 224 0.0 0.3 00:00:09 2-03:02:31 dlog
247 224 0.0 0.6 00:00:33 2-03:02:31 ds
248 224 0.3 2.8 00:09:59 2-03:02:31 mgmtApp
249 224 0.0 0.3 00:00:16 2-03:02:31 sys2swlog
251 224 0.0 0.4 00:00:06 2-03:02:30 fc2
252 224 0.0 0.6 00:00:16 2-03:02:30 nserver
253 224 0.0 0.8 00:00:08 2-03:02:30 PortApp
254 224 0.0 0.5 00:00:03 2-03:02:30 qfsApp
255 224 0.0 0.5 00:00:09 2-03:02:30 mserver
256 224 0.0 0.7 00:00:06 2-03:02:30 eport
257 224 0.0 0.6 00:00:13 2-03:02:30 zoning
282 254 0.0 0.5 00:00:00 2-03:02:26 qfsApp
284 224 0.0 0.6 00:00:08 2-03:02:26 snmpservicepath
285 282 0.0 0.5 00:00:00 2-03:02:26 qfsApp
308 224 0.0 0.8 00:00:29 2-03:02:25 cim_server
Elapsed time between resets
The uptime command displays the elapsed time since the switch was last reset and the reset method.
Note that a hot reset or non-disruptive firmware activation does not reset the elapsed time reported by this
command. The following example displays the time since the last reset.
SN6000 FC Switch #> uptime
Elapsed up time : 0 day(s), 2 hour(s), 28 min(s), 44 sec(s)
Reason last reset: NormalReset
Configuration information
The show config command displays a variety of configuration information at the port and switch levels.
In addition to the basic switch configurations, the show config command displays parameters that
control how data is maintained in the security and zoning databases. The show config command
displays the following types of information:
Switch configuration parameters, page 39
Zoning configuration parameters, page 39
Security configuration parameters, page 40
See alsoDisplaying port information” (page 57).

Table of Contents

Other manuals for HP StorageWorks SN6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks SN6000 and is the answer not in the manual?

HP StorageWorks SN6000 Specifications

General IconGeneral
BrandHP
ModelStorageWorks SN6000
CategorySwitch
LanguageEnglish

Related product manuals