HP StorageWorks SN6000 Fibre Channel Switch Command Line Interface Guide 193
set alarm
Description Controls the display of alarms in the session output stream or clears the alarm log.
Authority Admin session for the clear operand. Otherwise, none.
Syntax
set alarm [option]
Operands
[option]
Table 31 describes the output stream alarm parameters.
Table 31 Output stream alarm parameters
Parameter Description
clear Clears the alarm log history. This value requires an Admin session.
on Enables the display of alarms in the session output stream.
off Disables the display of alarms in the session output stream.
Disabling the display of alarms in the output stream allows
command scripts to run without interruption.
Examples The following is an example of the set alarm command:
SN6000 FC Switch #> set alarm on