EasyManuals Logo
Home>HP>Switch>StorageWorks SN6000

HP StorageWorks SN6000 Command Line Interface Guide

HP StorageWorks SN6000
330 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #307 background imageLoading...
Page #307 background image
HP StorageWorks SN6000 Fibre Channel Switch Command Line Interface Guide 307
zoning clear
Description Clears all inactive zone sets from the volatile edit copy of the zoning database. This operand
requires a zoning edit session. This operand does not affect the non-volatile zoning database.
However, if you enter the zoning clear command followed by the zoning save command, the
non-volatile zoning database will be cleared from the switch.
TIP: The preferred method for clearing the zoning database from the switch is the reset zoning
command.
Authority Admin session and a Zoning Edit session.
Syntax
zoning clear
Examples The following is an example of the zoning clear command:
SN6000 FC Switch #> admin start
SN6000 FC Switch (admin) #> zoning edit
SN6000 FC Switch (admin-zoning) #> zoning clear
SN6000 FC Switch (admin-zoning) #> zoning save
See also zoning save, page 317