HP StorageWorks SN6000 Fibre Channel Switch Command Line Interface Guide 265
show postlog
Description Displays the power-on self test log, which contains results from the most recently failed power-on self
test (POST).
Authority None
Syntax
show postlog
or
show post log
Examples The following is an example of the show postlog command:
SN6000 FC Switch #> show postlog
Queue: POST
Sequence Count: 467
Success Count: 452
Failed Count: 42
Records: 53
Record: 1 of 53
Time: day mmm dd hh:mm:ss yyyy
Sequence Number: 5
Consecutive Passes: 5
Record: 2 of 53
Time: day mmm dd hh:mm:ss yyyy
Sequence Number: 6
Test: TEST_SUITE_POST (0x13)
Subtest: TEST_STATIC_PORTADDR (0x72)
Fault Code: DIAGS_ERR_CPORT_VERIFY (0x34)
Loops: 0
Blade/Asic: 0/0
Register Address: 0x00000005
Received Data: 0x0082202b
Expected Data: 0x00a2202b
.
.
.