HP StorageWorks SN6000 Fibre Channel Switch Command Line Interface Guide 317
zoning save
Description Saves changes made during the current Zoning Edit session. The system informs you that the zone set
must be activated to implement any changes.
Authority Admin session and a Zoning Edit session.
Syntax
zoning save
Examples The following is an example of the zoning save command:
SN6000 FC Switch #> admin start
SN6000 FC Switch (admin) #> zoning edit
SN6000 FC Switch (admin-zoning) #>
.
.
SN6000 FC Switch (admin-zoning) #> zoning save
The changes have been saved; however, they must be activated
before they can take effect -- see zoneset activate command.
See also zoning edit, page 310