Maintenance Guide
3-2
3-1-2 Replacing the Filter
1) Shut-down the main compressed air.
2) Remove the air tube connected to the solenoid valve (φ4 × 8).
Remove the filter box U.(O-ring is mounted under the filter box U. Carefully handle this O-ring so
that it is not lost.)
* The filter box U differs depending on the serial number.
3) Exchange the filter. Please see the figure below.
*
Filter with flat tip and no protrusion. Part No.:40046646
*
Filter with protrusion at the tip. Part No.:E3052729000
(RS-1 machine Rev. N, RS-1R machine Rev. D, RS-1/1R head Rev. C or later)
4) Reassemble the parts and components in the reverse order of disassembly.
5) After the solenoid valves have been replaced, check the filter through the head vacuum ON/OFF
of the manual control.
3-1-3 Replacing the Filter for Release to Atmosphere
1) Shut-down the main compressed air.
2) Remove the cable connected to the solenoid valve.
3) Remove the fall prevention metal fittings and replace the filter for release to atmosphere.
4) Reassemble the parts and components in the reverse order of disassembly.
06
③
:
Filter ③ Part No.:E3052729000
(RS-1 machine Rev. N, RS-1R machine Rev. D,
RS-1/1R head Rev. C or later)
Filter for release to atmosphere
(Fall prevention metal fittings and
Round head screw: 4 pieces)