Maintenance Guide
5-31
5-14 Switching the Conveyor Direction
5-14-1 Switching the Conveyor Direction
1) Switching WAIT 2 sensor
① There are two sensors at the center of conveyance, select either one according to flow
direction.
Left to right flow Use the sensor on the front left side of the unit.
Right to left flow Use the sensor on the front left side of the unit.
② Remove the fiber from the WAIT2 sensor amplifier unit, Replace it with a fiber that is not
inserted.
* Insert the fiber so that the front side of the machine projects light and the back side receives
light.
From left to right case
From right to left case
Light emitting side
Light receiving side