Maintenance Guide
11-6
11-4 Replacing the Safety Cover Lock Cylinder
[Removal]
1) Loosen the M4×10 SEMS cap bolts (2 pcs.) and pull out the COVER in the direction
indicated by an arrow to detach it.
2) Remove the M6×12 SEMS cap bolts (2 pcs.) to detach the SC_LOCK unit .
SC_LOCK unit is located
at 2 locations inside the
machine main unit.
SCL_COVER
SC_LOCK unit
M6×12 SEMS cap
bolt (2 pcs.)
M4×10 SEMS cap
bolt (2 pcs.)