Maintenance Guide
5-37
5-15-2 Replacing the Stopper Cylinder
1) Shut down the air to the main unit.
2) Disconnect the air tubes that are connected to the cylinder.
3) Remove the cylinder from the mechanical stopper body together with the stopper connect.
4) Remove the stopper connector from the cylinder.
5) Remove the fitting.
6) Replace the cylinder.
7) Reassemble the components in the reverse order of disassembly.
∗ Carefully check the length adjustment of the cylinder rod and stopper connect.
∗ Assemble the cylinder at a position where the rod moves smoothly.
∗ Carefully check the air tube connections.
Figure 5-15-2-1 Replacing the Stopper Cylinder
Figure 5-15-2-2 Adjusting the stopper connect
Stopper Connect
8.6±0.2mm