Maintenance Guide
5-30
5-13 Replacing the Support Guide Cylinder
1) Detach the support table while referring to section 5-11, Replacing the Support Table Motor
(Replacing the BU Table Motor).
2) Remove the nuts and screws to detach the cylinder. (Two points on the left and right)
3) Install the new cylinder on the support table and fix the nut so that the distance between the
support table end and U_RELEASE_SUPPORT_BS is 22.5 mm at the position where the
cylinder rod is extended.
4) At this time, secure the sensor at the position between the position where the sensor is
moved in the direction indicated by an arrow mark from the cylinder rear end and starts
lighting and the position where the sensor goes off.
5) Return the lock nut of the speed controller three rotations from its fully closed position, and
then secure the lock nut.
6) Reassemble the support table while referring to section 5-11, Replacing the Support Table
Motor (Replacing the BU Table Motor).
Figure 5-13-1 Support Guide Cylinder
BU_RELEASE_SUPPORT_BS