Maintenance Guide
1-28
1-5. Replacing the Cableveyor Link
1-5-1. X Cableveyor Structure and Part Names
1-5-2. Detaching the Arm and Lock Stay
Follow the steps below to detach the arm and lock stay.
Wear cotton gloves since the geralyn (white cream) is sticking to the cable inside the
cableveyor.
1) Hold the arm.
2) Turn the arm around the shaft
to detach it.
3) Pull out the arm.
Part No./Part name:
40110451 X_CABLE_BEAR
Bracket at movement end
Joint link
Link
Arm
Joint link
Lock stay
Bracket at fixed end