JUNOS Internet Software Network Operations Guide: Hardware
350 ! Monitoring the SFM Status
Alternative Action If the SFM summary command output indicates that there is a problem, you can
display more detailed SFM status information with the following CLI command:
user@host> show chassis sfm detail
The command output displays the following information:
Sample Output user@host> show chassis sfm detail
SFM status:
Slot 0 information:
State Online
SPP Temperature 36 degrees C / 96 degrees F
SPR Temperature 45 degrees C / 113 degrees F
Total CPU DRAM 64 Mbytes
Total SRAM 4 Mbytes
Internet Processor I Version 1, Foundry IBM, Part number 3
Start time: 2001-12-03 05:08:45 PST
Uptime: 6 hours, 41 minutes, 17 seconds
Slot 1 information:
[...Output truncated...]
Slot 2 information:
[...Output truncated...]
Slot 3 information:
[...Output truncated...]
Packet scheduling mode: Disabled
What It Means In addition to the command output displayed for the show chassis sfm command,
the
show chassis sfm detail command displays the temperature of air passing by
the Switch Plane Processor (SPP) card and the Switch Plane Router (SPR) card (the
two SFM serial components) in degrees Centigrade. The command output displays
the total CPU DRAM and SRAM being used by the SFM processor. It also displays the
time when the SFM became active and how long the SFM has been up and running.
A small uptime means that the SFM came online a short time ago and could
indicate a possible SFM error condition.
Alternative Action To display the status of a particular SFM, use the following CLI command:
user@host> show chassis sfm sfm-slot
Alternative Action To display detailed status information about a particular SFM, use the following CLI
command:
user@host> show chassis sfm detail sfm-slot