! 381
Chapter 29
Monitoring the CIP
You monitor the Connector Interface Panel (CIP) to ensure management connection
to the M40e, M160, M320, T320, and T640 routing node Routing Engines, Building
Integrated Timing Source (BITS) interfaces for the Miscellaneous Control Subsystem
(MCS), and alarm relay contacts. (See Table 91.)
Table 91: Checklist for Monitoring the CIP
Tasks for Monitoring the CIP Command or Action
Understanding the CIP on page 382
Monitoring the CIP Status on page 384
show chassis environment
Checking for CIP Alarms on page 385
1. Display Current CIP Alarms on page 385 show chassis alarms
2. Display CIP Error Messages in the System Log File on
page 385
show log messages
3. Display CIP Error Messages in the Chassis Daemon Log File
on page 386
show log chassisd
Verifying CIP Failure on page 386
1. Check the CIP Connection on page 386 Check the connector screws on the CIP faceplate.
2. Check the Ethernet Port Functionality on page 386 1. Connect to the Ethernet port.
2. Check the
LINK LED.
3. Run the JUNOS software CLI.
3. Performing a CIP Swap Test on page 387 1. Power down the router.
2. Remove the CIP.
3. Replace the CIP with one that you know works.
4. Power on the router.
Getting CIP Hardware Information on page 388
1. Display CIP Hardware Information on page 388 show chassis hardware
2. Locating the CIP Serial Number ID Label on page 389 Look on the top of the left side of the CIP.
Replacing the CIP on page 389
Power down the router. To replace and return a CIP, follow the
instructions in the M40e or M160 router hardware guide.