5.6.7 PING Confirmation
Description
It is possible for this PBX to confirm the connection of IP telephones, routers, and hubs within or outside the
private network using PING. The PBX will send an Internet Control Message Protocol
(ICMP) echo request
through the PC programming terminal and receive an ICMP message confirming connection.
Conditions
This PBX performs PING as follows:
Test packet length: 56 bytes
Ping attempts: 5
Time out length: 1 second
Ping interval time: 1 second
PC Programming Manual References
7.1.2 Utility—Diagnosis—Ping