RL78/G10 CHAPTER 12 SERIAL ARRAY UNIT
R01UH0384EJ0311 Rev. 3.11 304
Dec 22, 2016
12.4.2 Stopping the operation by channels
The stopping of the operation by channels is set using each of the following registers.
Figure 12-21. Each Register Setting When Stopping Operation by Channels
(a) Serial channel stop register 0 (ST0) … This register is a trigger register that is used to enable stopping
communication/count by each channel.
(b) Serial Channel Enable Status Register 0 (SE0) … This register indicates whether data
transmission/reception operation of each channel is enabled or stopped.
(c) Serial output enable register 0 (SOE0) … This register is a register that is used to enable or stop output
of the serial communication operation of each channel.
(d) Serial clock output register 0 (CKO0) …This register is a buffer register for serial output of each
channel.
Symbol: 7 6 5 4 3 2 1 0
CKO0
0
0
0
0
0
0
CKO01
Note
0/1
CKO00
0/1
1: Serial clock output value is “1”
* When using pins corresponding to each channel as port function pins, set the corresponding CKO0n bit to “1”.
(e) Serial output register 0 (SO0) …This register is a register that is used to set a value of serial output of
each channel.
Note 16-pin products only.
Remarks 1. n: Channel number (n = 0, 1)
2. : Setting disabled (fixed by hardware), 0/1: Set to 0 or 1 depending on the usage of the user
Symbol: 7 6 5 4 3 2 1 0
ST0
0
0
0
0
0
0
ST01
0/1
ST00
0/1
1: Clears the SE0n bit to 0 and stops the communication operation
* Because the ST0n bit is a trigger bit, it is cleared immediately when SE0n = 0.
Symbol: 7 6 5 4 3 2 1 0
SE0
0
0
0
0
0
0
SE01
0/1
SE00
0/1
0: Operation stops
* The SE0 register is a read-only status register. Operation is stopped by using the ST0
register.
For a channel whose operation is disabled, the value of the CKO0n bit of the SO0 register
can be set by software.
Symbol: 7 6 5 4 3 2 1 0
SOE0
0
0
0
0
0
0
SOE01
Note
0/1
SOE00
0/1
0: Stops output by serial communication operation
* For channel n whose serial output is stopped, the SO0n bit value of the SO0 register can be set by
software.
Symbol: 7 6 5 4 3 2 1 0
SO0
0
0
0
0
0
0
SO01
Note
0/1
SO00
0/1
1: Serial data output value is “1”
* When using pins corresponding to each channel as port function pins, set the corresponding SO0n bit to “1”.

Table of Contents