8.17.4 Motorized potentiometer as setpoint source
Function description
The "Motorized potentiometer" function emulates an electromechanical potentiometer. The
output value of the motorized potentiometer can be set with the "higher" and "lower" control
signals.
0RWRUL]HGSRWHQWLRPHWHU
VHWSRLQWDIWHUWKHUDPS
IXQFWLRQJHQHUDWRU
5DLVH
/RZHU
0DLQVHWSRLQW
6FDOLQJ
6FDOLQJ
6XSSOHPHQWDU\VHWSRLQW
S
S
S
S
S
U
U
S
U
Figure8-35 Motorized potentiometer as setpoint source
023ORZHU
023UDLVH
Q
PD[
Q
PD[
6HWSRLQW
21
2))
S
U
S
S
SS
W
W
W
W
Figure8-36 Function chart of the motorized potentiometer
Example
Setting with the motorized potentiometer as setpoint source:
Parameter Description
p1070 = 1050 Interconnects the main setpoint with the motorized potentiometer output.
Advanced commissioning
8.17Setpoints
SINAMICS G120C Converters
274 Operating Instructions, 02/2023, FW V4.7 SP14, A5E34263257B AK

Table of Contents

Other manuals for Siemens SINAMICS G120C DP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G120C DP and is the answer not in the manual?

Siemens SINAMICS G120C DP Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS G120C DP
CategoryInverter
LanguageEnglish

Related product manuals