9.7.2.2. Options – 324
Further optional parameters can be set here:
3241 – Paper Feed
Sets whether the automatic paper feed is
to be activated.
Possible settings: >YES< or >NO<
‘YES’
3242 – Reverse Eject
Sets whether or not the paper ejection
is to be reversed.
Possible settings: >YES< or >NO<
3243 – Printing Mode
Exclusive access:
The printer is used exclusively by the MultiLevel system.
Shared access:
The printer interfaces of several systems are connected to one common printer.
The printer manager (parameter 3124) controls access.
Network:
The printer is connected only to the printer manager (parameter 3124). If other
systems want to print, they must send the print data via CAN bus to the printer
manager.
‘Network’
3244 – Page Width
‘35’.
9.7.2.3. Driver – 325
Parameters specific to the printer drivers can be set here:
Changes should be made only after
consulting F.A. Sening.
9.7.2.3.1. General – 3251
General parameters specific to the printer drivers can be set here. The control sequences are
entered in hexadecimal. Details are to be taken from the manual for the printer employed. The
factory setting corresponds to the control sequences for a printer with ESCIP control:
MultiLevel Instruction Manual MENU structure