MultiLevel Instruction Manual MENU structure
------------------------------------------
3611 Driver Number 0
3612 Driver Name Driver 1
3613 Master Keyword 0
3621 Driver Number 0
3622 Driver Name Driver 2
3623 Master Keyword 0
3631 Driver Number 0
3632 Driver Name Driver 3
3633 Master Keyword 0
3641 Driver Number 0
3642 Driver Name Driver 4
3643 Master Keyword 0
3651 Driver Number 0
3652 Driver Name Driver 5
3653 Master Keyword 0
3661 Driver Number 0
3662 Driver Name Driver 6
3663 Master Keyword 0
3671 Driver Number 0
3672 Driver Name Driver 7
3673 Master Keyword 0
3681 Driver Number 0
3682 Driver Name Driver 8
3683 Master Keyword 0
3691 Driver Number 0
3692 Driver Name Driver 9
3693 Master Keyword 0
3601 Driver Number 99999999
3602 Driver Name Master
3603 Master Keyword 98765432
end
9.3.1.2. Setup <F3> – PTB parameter list
Only the parameters protected by W&M will be printed.
See also chapter 9.3.1.1 "Setup <F1> – Complete Parameter List".
Parameter (sample printout!)
16.05.2011 13:18:34
Device : MultiLevel
------------------------------------------
Version : 1.23[1.27]DE
Sealcounter : 000002
Serial no. : ????????
Comp. no. : - ? -
------------------------------------------
Seal broken!
------------------------------------------
Parameter CRC : 77A5
------------------------------------------
Local CANbus
------------------------------------------
+ 3112 Level-IF 1
+ 3114 Wetleg-IF 1
Global CANbus
------------------------------------------
Compartments
------------------------------------------
+ 3131 No of comp. 3
+ 3132111 LevelSensor-No. 1
+ 3132112 Temp.Sensor-No. 1
+ 3132113 WetlegSensor-No. 1
+ 3132114 Level Serial 3000
+ 3132121 Zero Levelsensor 0
+ 3132122 Oset Ice Prot. 25000
+ 3132123 Oset Slope table 0
+ 3132124 Oset Float 0
+ 3132125 X Oset Level 0
+ 3132126 Y Oset Level 0
+ 3132127 Oset Temp. 0.0
.
.
.
.
.
.
+ 3132142 Max. Pitch Slope 3.00
+ 3132143 Min. Roll Slope -3.00
+ 3132144 Max. Roll Slope 3.00
+ 3132145 Min. Dlv. Volume 5000
+ 35189 Float Correction 1050
+ 351911 Product Name Bio Fuel Oil
+ 35192 Product Type Liquid Product
+ 35193 W&M Code 9
+ 351971 Compensation JA
+ 351972 Comp. temperature 15
+ 351973 Comp. method 54B
+ 351974 Average Density 831.0
+ 35199 Float Correction 800
Driver List
------------------------------------------
End

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TechnipFMC Sening MultiLevel and is the answer not in the manual?

TechnipFMC Sening MultiLevel Specifications

General IconGeneral
BrandTechnipFMC
ModelSening MultiLevel
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals