MultiLevel Instruction Manual Other Information
13 – Other Information
13.1. Abstract from ElexV (§12)
Inspections
(1) The operator must arrange for the electrical devices to be inspected for the proper
condition of their assembly, installation and operation by a qualified electrician or
directed and supervised by a qualified electrician.
1. before first use
2. in specific time intervals.
The periods must be calculated so that resulting deficiencies, which must be assumed,
are determined in a timely manner. The inspections according to sentence 1 no. 2 must
be carried out every three years. They may be omitted if the electrical devices are
constantly monitored by a responsible engineer.
(2) During the inspection, related standard engineering practices must be followed.
(3) If requested by the relevant authority, a test book with specific entries must be kept.
(4) In case of damage or in special cases, the regulating authority may arrange a special
inspection by an expert. The operator must arrange that an assigned inspection,
executed according to sentence 1, is carried out.
Abstract from Bundesarbeitsblatt 3/1997 page 101
(German Labor Bureau Sheet 3/1997)
13.2. Maintenance
The devices must not be modified mechanically or electronically in any way.
During cleaning with a steam cleaner orwith pressurised water, the devices
should be protected from the water jet. Never aim the steam jet directly onto
the devices!
We cannot accept responsibility for any damage caused by moisture in the
equipment as a result of improper cleaning procedures.
For all devices, a regular safety check in accordance with industrial safety
regulations must be carried out. Equipment and protective systems which
fall under the scope of EC Directive 94/9/EC and are operated in hazardous


13.2.1. Maintenance Plan
daily weekly monthly annually
Clean the outside of the device X
Visual testing X
Checking the LED's X
Examination of the case

X
Check the cable and check
function with GWG
X

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TechnipFMC Sening MultiLevel and is the answer not in the manual?

TechnipFMC Sening MultiLevel Specifications

General IconGeneral
BrandTechnipFMC
ModelSening MultiLevel
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals