MultiLevel Instruction Manual MENU structure
9.7.1.4.3.1. Valve Control – 31431
Possible settings:
"automatic" / "manual"
MultiLevel is operated without NOMIX,
i.e. the MultiLevel is equipped with its
own I/O interface and controls the foot
and line valves itself.
If set to <manual> (factory setting), the
foot valves remain closed when switching
to loading mode (exception: compartment
monitoring). To start loading in this case,
the individual foot valves must be opened
manually by entering the compartment
number.
If set to <automatic>, the foot valves are opened automatically when switching
to loading mode. A loading operation can be stopped (foot valve is closed) and
restarted (foot valve is opened) by entering the compartment number.
9.7.1.4.3.2. Loadplan Query – 31432
YES / NO, only relevant to operation
without NOMIX.
YES:
load plan is initially input manually.
9.7.1.4.3.3. Loading Measurement – 31433
YES / NO
Measurement of volume loaded incl. TK
of receipt at end of loading.