MultiLevel Instruction Manual Remote Access to NoMix
4 – Remote Access to NoMix
The basic screen is normally displayed after switching on and is in the basic state:
NoMix can also be operated without its own display. MultiLevel then displays
the NoMix information.
The MultiLevel display automatically switches over to NoMix if a "full screen
error" has occurred in NoMix.
In normal operation, the switchover must be made by the operator.
CAUTION:
During "Discharge" or "Loading", you MUST NOT switch over from one
operating mode ("Discharge" / "Loading") to the other directly!
4.1. Loading
The basic screen is normally displayed after switching on and is in the basic state:
Start Screen
Operation:
By pressing the <F1> button change in
the loading mode.
Loading Screen (1)
Operation:
By pressing the <F2> button change in
the individual compartments are displayed
as percentages in bar charts.