MultiLevel Instruction Manual MENU structure
In the case of operation with NOMIX, the loading plan can only be viewed.
Changes to the loading plan are not possible here.
In the case of operation without NOMIX, the loading plan can/must be edited by
the driver. Here, the parameter 31411
• 31411 = ‘always’: A change is also possible when the compartment is full
• 31411 = ‘empty’: A change is possible only when the compartment is empty.
9.7.1.4.2. Delivery – 3142
Press <1> to select the volume preset.
9.7.1.4.2.1. Sub-menu for volume preset - 31421
Explanation of the submenus
1 Preset Query
2 Preset Type
3 Auto-Adjust
9.7.1.4.2.1.1. Preset Query – 314211
Possible settings:
YES / NO.
If set to <YES> (factory setting), the
preset volume is queried before the start
of each delivery. The standard preset for
the respective compartment (parameter
313xx52) is pre-entered in the input mask.
If an interrupted delivery is resumed,
there is an additional query as to whether
the delivery should continue with the
previously entered preset amount or
whether a new (additional) preset amount
is to be entered. The delivery stops upon
reaching the preset amount. If the delivery
is continued after that, then a new (additional) preset amount is queried.
If set to <NO>, the volume preset will not be queried at the start of the delivery.