7.1.6. Stand-alone mode
In stand-alone mode, the I/O interface (chapter 7.8 "I/O interface - NM2IO") is
connected directly to the MultiLevel for the control of the foot and line valves.
As a result of that, all information from the NOMIX system is omitted:
• The loading plan must now be entered manually.
• No information is available about connected hoses/level sensors etc.
• No information is available about the readiness of a compartment for delivery
(i.e. whether a compartment is completely and correctly connected).
• Mixing protection is likewise not guaranteed; this is the responsibility of the operator.
As a result of omission of the NOMIX system, the operating sequences for filling and delivery
are also changed:
When changing to loading mode, the foot valves can be opened automatically
Filling must be stopped manually.
There is no mixing protection.
ATTENTION:
Changes for delivery:
The operator must start a compartment manually!
There are no safety precautions (hose monitoring, product recognition!
Interruption / termination of a delivery is likewise done manually.
7.2. Wet leg sensor interface – NM2WET-E
Parts no.: NM2WET-E
Wiring diagram no.: 51.351346
Figure 35: Wet Leg Sensor Interface – NM2WET-E
MultiLevel Instruction Manual Modules