MultiLevel Instruction Manual Parameter List
16 – Parameter List
16.1. Parameter Table (V1.29)
No. Name K Factory
Setting
Meaning
1 Display Cong.
1.2 Date and Time F
E
Set internal clock
ATTENTION: Date is calibration-protected!
1.3 User’s Language F German Display language for menus, alarms and reports
1.4 Customer's Lang. F German Display language for deliveries and receipts
2 Loading Plan F
3 Parameter List
3.1 Device Settings
3.1.1 Local CAN bus
3.1.1.1. Terminals M 1 Number of operating devices connected.
ATTENTION:
3.1.1.2. Level IF E 1 Number of level sensor interfaces connected
3.1.1.4. Wetleg-IF E 1 Number of wet leg interfaces connected
3.1.1.5. IO-IF E 0 Number of I/O interfaces connected
3.1.2. Global CAN-bus
3.1.2.1. Global Node No. M 1 Node number (address) of MultiLevel on the CAN bus.
0 No CAN communication

2-31 Node numbers of additional devices.
3.1.2.2. OBC node M 0 Node number of the On-Board computer.
0 No communication with OBC (not available
21 Standard node number of the OBC
3.1.2.3 NOMIX node M 11 Node number of the NOMIX system.
0 No communication with NOMIX (not available)
11 Standard node number of NOMIX
3.1.2.4 Printer admin M 1 Node number of the printer manager
3.1.2.5 Time target M 1 Node number for time synchronization
3.1.3 Compartments
3.1.3.1 No of compartments E 3 Number of compartments in the tank truck
3.1.3.2
...
3.1.3.4.
Compartments 1-10
Compartments 21-30
See separate table
3.1.3.5. Comp. monitoring
3.1.3.5.1. At loading M OFF Compartment monitoring mode during loading:
- OFF
- Without foot valves
- FV only at start
- FV only at end
- FV at start and end
3.1.3.5.2. At delivery E OFF Compartment monitoring mode during delivery (see above)
3.1.4 Operation options
3.1.4.1 General
3.1.4.1.1 Change Lplan M always Enable changes to loading plan:
- always 
- empty Only possible with empty compartment
3.1.4.2 Delivery
3.1.4.2.1 Preset
3.1.4.2.1.1 Preset Query M YES Activates / deactivates volume preset
3.1.4.2.1.2 Preset Type M V0 Type of volume preset:
V0 Volume preset to compensated volume
VT Volume preset to uncompensated volume

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TechnipFMC Sening MultiLevel and is the answer not in the manual?

TechnipFMC Sening MultiLevel Specifications

General IconGeneral
BrandTechnipFMC
ModelSening MultiLevel
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals