Oil volume
When changing with filter 19
Viscosity grade should be selected depending on the temperature outside.
6.8.2 Fuel system
Fuel
Type Diesel fuel which conforms to EN 590:2009 norm
Feed pump Mechanical pump
Standard tank 380 liters
Forest tank 250 liters
Injection system
Common rail injection High-pressure pump with electronic injection control
6.8.3 Selective catalytic reduction system
System type Bosch DENOXTRONIC 2.2+
Fluid type DIN70070/ISO22241-certified AdBlue/DEF
Tank capacity 70 liters
Forest tank capacity 45 liters
6.8.4 Air cleaner
Air cleaner
Two-stage, dry element, with blockage indicator
Pre-cleaner system Ejector
6.8.5 Cooling system
Pump
Centrifugal
Radiator Pressurised with expansion tank regulated by
pressure cap
Thermostat 2 thermostats: 79°C and 83°C
Fan The belt-driven fan is controlled by the engine's
control module for precise fan speed modulation
Coolant Engine coolant mixed with water. ASTM D6210 Type
I-FF, ASTM D3306.
In first fill, OAT-coolant (Organic Acid Technology)
used, not recommended to mix with old type of
coolants.
Coolant, Valtra grade
Valtra Coolant
Coolant volume 28 litres
6.9 Electrical system
Ground
Negative
Voltage 12 V
Battery 174 Ah
Table continued on next page
6. Technical specifications
- 389 -