DRIVING OPERATION
FH12N059
SIGNALIZATION OF TRAVEL CLUTCHES AND GEAR BOX SYSTEM FAILURES
The failures in systems of travel clutches and gear box are signalized by red controls
on the dashboard and a failure code on the display.
1 - Clogging of delivery filter of gear box switchboard control. It lights up with clogging
of delivery filter of gear box switchboard. If it lights up, replace delivery filter of
gear box switchboard insertion.
2 - Gear box oil overheating control. If it lights up, interrupt your work and allow the
tractor to run on idle run, until the oil filling of gearbox cools off and the control
switches off. After the control switches off, you can continue working with the trac-
tor without restrictions.
3 - Gearbox failure control. It lights up with serious failure of the system.
4 - Failure code and its description is displayed on the display