Fault tracing 131
Parameter errors
Code Error Cause What to do
6001 Parameter value out of range
(_ecPARAM_VALUE_OUT_OF_R
ANGE)
The value supplied for the
parameter is out of range.
The value you have entered or that is
stored in the parameter file (.ptx) you have
loaded does not fit within the limits
specified by the drive firmware version
loaded. If needed update the firmware first
then load the parameter file. To do this in
Mint Workbench go to Tools > Download
Firmware > Select and download firmware
file. Once complete try again
6004 Parameter definition has changed
(_ecPARAM_DEFINITION_ERRO
R)
The specified parameter
exists, but its definition has
changed.
Check the latest documentation for the
parameter.