Version 7.2 427 Mediant 1000B Gateway & E-SBC
User's Manual 19. Coders and Profiles
Parameter Description
can only function if the EnableEarlyAMD parameter is set to any
value other than [1].
ï‚§ This feature does not need the receipt of the SIP X-Detect header
in the incoming INVITE to activate the AMD.
ï‚§ The corresponding global parameter is AMDmode.
AMD Sensitivity Parameter
Suite
amd-sensitivity-parameter-suit
[IpProfile_AMDSensitivityPara
meterSuit]
Defines the AMD Parameter Suite to use for the Answering Machine
Detection (AMD) feature.
ï‚§ [0] 0 = (Default) Parameter Suite 0 based on North American
English with standard detection sensitivity resolution (8 sensitivity
levels, from 0 to 7). This AMD Parameter Suite is provided by the
AMD Sensitivity file, which is shipped pre-installed on the device.
ï‚§ [1] 1 = Parameter Suite based 1 on North American English with
high detection sensitivity resolution (16 sensitivity levels, from 0 to
15). This AMD Parameter Suite is provided by the AMD
Sensitivity file, which is shipped pre-installed on the device.
ï‚§ [2] 2 to [7]7 = Optional Parameter Suites that you can create
based on any language (16 sensitivity levels, from 0 to 15). This
requires a customized AMD Sensitivity file that needs to be
installed on the device. For more information, contact your
AudioCodes sales representative.
Note:
ï‚§ To configure the detection sensitivity level, use the 'AMD
Sensitivity Level' parameter.
ï‚§ For more information on the AMD feature, see Answering
Machine Detection (AMD) on page 200.
ï‚§ The corresponding global parameter is
AMDSensitivityParameterSuit.
AMD Sensitivity Level
amd-sensitivity-level
[IpProfile_AMDSensitivityLeve
l]
Defines the AMD detection sensitivity level of the selected AMD
Parameter Suite (using the 'AMD Sensitivity Parameter Suite'
parameter).
For Parameter Suite 0, the valid range is 0 to 7, where 0 is for best
detection of an answering machine and 7 for best detection of a live
call. For any Parameter Suite other than 0, the valid range is 0 to 15,
where 0 is for best detection of an answering machine and 15 for
best detection of a live call.
Note: The corresponding global parameter is AMDSensitivityLevel.
AMD Max Greeting Time
amd-max-greeting-time
[IpProfile_AMDMaxGreetingTi
me]
Defines the maximum duration (in 5-msec units) that the device can
take to detect a greeting message.
The valid range value is 0 to 51132767. The default is 300.
Note: The corresponding global parameter is
AMDMaxGreetingTime.
AMD Max Post Silence
Greeting Time
amd-max-post-silence-
greeting-time
[IpProfile_AMDMaxPostSilenc
eGreetingTime]
Defines the maximum duration of silence from after the greeting time
is over (configured by AMDMaxGreetingTime) until the device's AMD
decision.
Note: The corresponding global parameter is