Version 7.2 793 Mediant 1000B Gateway & E-SBC
User's Manual 46. Restoring Factory Defaults
46 Restoring Factory Defaults
This section describes how to restore the device's configuration to factory defaults.
46.1 Restoring Factory Defaults through CLI
You can restore the device to factory defaults through CLI, as described in the following
procedure.
 To restore factory defaults through CLI:
1. Access the CLI:
a. Connect the RS-232 serial port of the device to the communication port on your
computer. For serial cabling, refer to the Hardware Installation Manual.
b. Establish serial communication with the device using a serial communication
program (such as HyperTerminalTM) with the following communication port
settings:
♦ Baud Rate: 115,200 bps
♦ Data Bits: 8
♦ Parity: None
♦ Stop Bits: 1
♦ Flow Control: None
2. At the CLI prompt, type the username (default is "Admin" - case sensitive), and then
press Enter:
# Username: Admin
3. At the prompt, type the password (default is "Admin" - case sensitive), and then press
Enter:
# Password: Admin
4. At the prompt, type the following, and then press Enter:
# enable
5. At the prompt, type the password again, and then press Enter:
# Password: Admin
6. At the prompt, type the following to reset the device to default settings, and then press
Enter:
# write factory
46.2 Restoring Factory Defaults through Web Interface
You can restore the device to factory defaults through the Web interface.
Note: When restoring to factory defaults, you can preserve your IP network settings
that are configured in the IP Interfaces table (see ''Configuring IP Network Interfaces''
on page 135), as described in the procedure below. This may be important, for
example, to maintain connectivity with the device (through the OAMP interface) after
factory defaults have been applied.

Table of Contents

Other manuals for AudioCodes MediaPack MP-11 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MediaPack MP-11 Series and is the answer not in the manual?

AudioCodes MediaPack MP-11 Series Specifications

General IconGeneral
BrandAudioCodes
ModelMediaPack MP-11 Series
CategoryGateway
LanguageEnglish

Related product manuals