Version 7.2 931 Mediant 1000B Gateway & E-SBC
User's Manual 62. Configuration Parameters Reference
Parameter Description
[TelnetServerEnable]
ï‚§
[1] Enable Unsecured (default)
ï‚§ [2] Enable Secured
Note: Only the primary Web User Account (which has Security
Administration access level) can access the device using Telnet (see
''Configuring Management User Accounts'' on page 65).
Telnet Server TCP Port
configure system > cli-
settings > telnet-port
[TelnetServerPort]
Defines the port number for the embedded Telnet server.
The valid range is all valid port numbers. The default port is 23.
Telnet Server Idle Timeout
configure system > cli-
settings > idle-timeout
[TelnetServerIdleDisconnect]
Defines the timeout (in minutes) for disconnection of an idle Telnet
session. When set to zero, idle sessions are not disconnected.
The valid range is any value. The default is 0.
Note: For the parameter to take effect, a device reset is required.
Maximum Telnet Sessions
configure system > cli-
settings > telnet-max-
sessions
[TelnetMaxSessions]
Defines the maximum number of permitted, concurrent Telnet/SSH
sessions.
The valid range is 1 to 5 sessions. The default is 2.
Note: Before changing the value, make sure that not more than this
number of sessions are currently active; otherwise, the new setting will
not take effect.
[CLIPrivPass] Defines the password to access the Enable configuration mode in the
CLI.
The valid value is a string of up to 50 characters. The default is
"Admin".
Note: The password is case-sensitive.
62.1.4 ini File Parameters
The parameters relating to ini-file management are described in the table below.
Table 62-4: ini File Parameters
Parameter Description
[INIPasswordsDisplayType]
Defines how passwords are displayed in the ini file.
ï‚§ [0] = (default) Disable. Passwords are obscured ("encoded"). The
passwords are displayed in the following syntax: $1$<obscured
password> (e.g., $1$S3p+fno=).
ï‚§
[1] = Enable. All passwords are hidden and replaced by an asterisk
(*).
62.1.5 SNMP Parameters
The SNMP parameters are described in the table below.
Table 62-5: SNMP Parameters
Parameter Description

Table of Contents

Other manuals for AudioCodes MediaPack MP-11 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MediaPack MP-11 Series and is the answer not in the manual?

AudioCodes MediaPack MP-11 Series Specifications

General IconGeneral
BrandAudioCodes
ModelMediaPack MP-11 Series
CategoryGateway
LanguageEnglish

Related product manuals