Version 7.2 951 Mediant 1000B Gateway & E-SBC
User's Manual 62. Configuration Parameters Reference
Parameter Description
auth-key-id
[NtpAuthKeyId]
server. The NTP server may have several keys configured for different
clients; this number identifies which key is used.
The valid value is 1 to 65535. The default is 0 (i.e., no authentication is
done).
NTP Authentication Secret
Key
auth-key-md5
[ntpAuthMd5Key]
Defines the secret authentication key shared between the device
(client) and the NTP server, for authenticating NTP messages.
The valid value is a string of up to 32 characters. By default, no key is
defined.
Regional Clock and Daylight Saving Time Parameters
UTC Offset
configure system > clock >
utc-offset
[NTPServerUTCOffset]
Defines the Universal Time Coordinate (UTC) offset (in seconds) from
the local time.
The valid range is -43200 to 43200. The default is 0.
Note: The offset setting is applied only on the hour. For example, if
you configure the parameter at 15:42, the device applies the setting
only at 16:00.
Daylight Saving Time
configure system > clock >
summer-time > summer-time
[DayLightSavingTimeEnable]
Enables daylight saving time (DST).
ï‚§ [0] Disable (default)
ï‚§ [1] Enable
Start Time / Day of Month
Start
configure system > clock >
summer-time > start
[DayLightSavingTimeStart]
Defines the date and time when DST begins. This value can be
configured using any of the following formats:
ï‚§ Day of year - mm:dd:hh:mm, where:
mm denotes month
dd denotes date of the month
hh denotes hour
mm denotes minutes
For example, "05:01:08:00" denotes daylight saving starting from
May 1 at 8 A.M.
ï‚§ Day of month - mm:day/wk:hh:mm, where:
mm denotes month (e.g., 04)
day denotes day of week (e.g., FRI)
wk denotes week of the month (e.g., 03)
hh denotes hour (e.g., 23)
mm denotes minutes (e.g., 10)
For example, "04:FRI/03:23:00" denotes Friday, the third week of
April, at 11 P.M. The week field can be 1-5, where 5 denotes the
last occurrence of the specified day in the specified month. For
example, "04:FRI/05:23:00" denotes the last Friday of April, at 11
P.M.
End Time / Day of Month
End
configure system > clock >
summer-time > end
[DayLightSavingTimeEnd]
Defines the date and time when DST ends. For a description of the
format of this value, see the DayLightSavingTimeStart parameter.
Offset
configure system > clock >
summer-time > offset
Defines the DST offset (in minutes).
The valid range is 0 to 120. The default is 60.
Note: The offset setting is applied only on the hour. For example, if