5. Advanced menu
Item
Setti ng
Function
NETWORK
CERTIFICATION
ON
/OFF
Select whether to enable the network certification or not. S elect OFF
for norm al use.
IP CONFIG
ENTER
Select t his setting for IP Configuration.
DHCP ON Select this setting w hen you o btain IP CONFIG automatically by
DHCP server.
OFF Select this setting when you set IP CONFIG manually.
IP ADDRESS
***.***.***.***
Press the ENTER key to set IP ADDRE SS. When DHCP is set to ON,
you cannot change this setting.
SUBNE T MASK
***.***.***.***
Press the ENTER k ey to set S UBN ET MAS K. When DHCP is set to
ON, you cannot change this setting.
DEFAULT GATEWAY
***.***.***.***
Press the E NTER key to s et DEFAULT GATEWAY. When DHCP is set
to ON, you cannot change this setting.
MAC ADDRE SS
xx-xx-xx-xx-xx-xx
Displays M AC ADDRESS.
SAV E SETTINGS
OK
Saves the IP CO NFIG settings. When the IP CONFIG is not c hanged,
you c annot selec t SAVE SETTINGS.
CONTROL SYSTEM
STANDARD
Select this se tting whe n u sing Projec tor Toolset.
AMX
Select when using a c ontroller made by A MX .
CRESTRON
Select this setting when using the controller or s oftware of Crestron
Electronics, Inc.
NETWORK RESET
OK
Resets the Network Setting.
NETWORK RESTART
OK
Press the ENTER key to restart the network fu nction.
• AMX does not support network c ertification. When setting CONTROL SYSTEM to AMX, set NETWORK CERTIFICATION to
OFF.
5.10 INFORMATION menu
Overview
IMAGE INSTALL1 INSTALL2
MULTI-
SCREEN
FEATURE SIGNAL NETWORK INFO
60.00 Hz
RESOLUTION
1024 x 768
VERTICAL
FREQUENCY
48.36 kHz
5 WIRE
HORIZONTAL
FREQUENCY
SYNC. TYPE
SERIAL NUMBER
FILTER TIME
*****
H
********
...
NEXT LAMP RELAY
COMPUTER1INPUT
*
D
**
H
LAMP 1 TIME (LOW)
LAMP 2 TIME (LOW)
****
H
****
H
Image 5-20
Item Description
LAMP 1 TIME (LO W ) This item shows the lamp operation time calculated based on that the LAMP MODE of LAMP
1isLOW.
→ When the LAMP MODE is STANDARD, this item shows a longer lamp oper ating time than
the actual time.
→ When the lam p operating time is 0 to 10 hours, “0H” is displayed. The lamp operating time
exceeding 10 hours is indicated by the actual hours.
→ When the lamp operating time reaches 3 000 hours, the bar turns to y ellow. When it reaches
3800 hours, the bar turns to re d.
→ The icon displayed to the right of the bar shows the lamp status. Yellow: On, Red: End of lam p
life or error such as illumination failure, Black: Off
52 R5905597 PHXX SERIES 20/05/2014