from Level1(1) to Level5(5) or from Level6(6) to Level31(31). You can specify the function
when the Smart Pool is enabled.
18. From the New Page Assignment Tier list, select a new page assignment tier. You can select
from levels High, Middle, and Low.
You can specify the function when the Smart Pool is enabled.
19. In the Relocation Priority option, select a priority.
To relocate the LDEV preferentially, set Prioritize. You can select Default or Prioritize. You can
specify this function when the Smart Pool is enabled.
20. If necessary, change the settings of the V-VOLs.
You can change the following settings:
Editing SSID
Click Edit SSIDs to open the Edit SSIDs window.
Changing the LDEV settings
Click Change LDEV Settings to open the Change LDEV Settings window.
21. If necessary, delete a row from the Selected LDEVs table.
Select a row to be deleted, then click Remove.
22. Click Add.
The created V-VOLs are added to the right Selected LDEVs table. If invalid values are set, an
error message appears.
The Provisioning Type, System Type, Emulation Type, Pool Selection, Drive Type/RPM, RAID
Level, LDEV Capacity, and Number of LDEVs field must be set. If these required items are not
registered, you cannot click Add.
23. Click Finish.
The Confirm window appears.
To continue the operation for setting the LU path and define LUN, click Next.
24. In the Task Name in the text box, enter the task name.
You can enter up to 32 ASCII characters and symbols in all, except for \ / : , ; * ? " < > |.
"yymmdd-window name" is entered as a default.
25. Click Apply.
If the Go to tasks window for status checkbox is selected, the Tasks window appears.
Editing a THP V-VOL's SSID
The Storage Administrator (Provisioning) role is required to perform this task.
Before registering a THP V-VOL, you may need to edit the THP V-VOL's SSID. The SSID is a
hexadecimal value.
1. In the Selected LDEVs table in the Create LDEVs window, click Edit SSIDs.
The Edit SSIDs window opens. The SSIDs table shows the SSID existing and to be added.
2. If you want to change the SSID, select the appropriate LDEV, then click Change SSIDs.
3. In the Change SSIDs window, type the new SSID in hexadecimal format, then click OK
4. In the Edit SSIDs window, click OK.
5. In the Create LDEVs window, click Finish.
6. In the Confirm window, confirm the settings, then click Apply.
If Go to tasks window for status is checked, the Tasks window opens.
Working with THP V-VOLs 135