3. Click Expand V-VOLs.
The Expand V-VOLs window opens. If the THP V-VOL is selected from the LDEV table in the
Logical Devices window, click More Actions, then click Expand V-VOLs.
4. Select Specify total capacity or Specify additional capacity
5. If you want to offset the specified LDEV capacity by boundary, change the default Offset
boundary from OFF to ON.
6. In Capacity, type the capacity amount.
Enter the LDEV capacity to two decimal places within the range of values indicated below the
text box.
7. Click Finish.
The Confirm window opens.
8. In the Confirm window, confirm the settings, in Task Name type a unique name for this task
or accept the default, then click Apply.
If Go to tasks window for status is checked, the Tasks window opens.
Changing the name of a THP V-VOL
The Storage Administrator (Provisioning) role is required to perform this task.
1. In the Remote Web Console main window, in the Storage Systems tree, select Logical Devices.
The following is another way to select LDEVs.
1. In the Remote Web Console main window, in the Storage Systems tree, select Pool.
The pool name appears below Pool.
2. Select the pool associated with the THP V-VOL you want to rename.
3. Select the Virtual Volumes tab.
2. From the table, select the THP V-VOL you want to rename.
3. Click Edit LDEVs.
When you selected THP V-VOLs from the Virtual Volumes table, click More Actions, then Edit
LDEVs.
The Edit LDEVs window opens.
4. Check LDEV Name and change the LDEV name, if necessary.
1. In Prefix, type the characters that will become the fixed characters for the beginning of
the LDEV name. The characters are case-sensitive.
2. In Initial Number, type the initial number that will follow the prefix name.
5. Click Finish.
6. In the Confirm window, confirm the settings, in Task Name type a unique name for this task
or accept the default, then click Apply.
If Go to tasks window for status is checked, the Tasks window opens.
About releasing pages in a THP V-VOL
Releasing pages in a THP V-VOL frees up pool capacity. When a page in the THP V-VOL contains
zero data, the free capacity of a pool increases after the pages are released. You can perform
the operation to reclaim zero pages on each V-VOL and monitor progress. For details, see “View
Pool Management Status window” (page 354). If you stop the operation to reclaim zero pages, the
zero pages that have been reclaimed cannot be restored.
Logically, there is no difference between a page with just zero data and the area of a THP V-VOL
without a page allotted. Both are effectively identical. However, the former uses pool capacity and
the latter does not.
Managing pools and THP V-VOLs 153

Table of Contents

Other manuals for HP XP7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP XP7 and is the answer not in the manual?

HP XP7 Specifications

General IconGeneral
BrandHP
ModelXP7
CategoryStorage
LanguageEnglish

Related product manuals