Goodrive270 series VFD for fan and pump Maintenance
-289-
8.3 Cooling fan
The service life of the cooling fan of the VFD is more than 25,000 hours. The actual service life of the
cooling fan is related to the use of the VFD and the temperature in the ambient environment.
You can view the running duration of the VFD through P07.14 (Accumulated running time).
The increase of the bearing noise indicates a fan fault. If the VFD is applied in a key position, replace
the fan once the fan starts to generate unusual noise. You can purchase spares of fans from INVT.
Cooling fan replacement:
 Read chapter 1 Safety precautions carefully and follow the instructions to
perform operations. Ignoring these safety precautions may lead to physical
injury or death, or device damage.
1. Stop the VFD, disconnect the AC power supply, and wait for a time no shorter than the waiting
time designated on the VFD.
2. Open the cable clamp to loose the fan cable.
3. Disconnect the fan cable.
4. Remove the fan with a screwdriver.
5. Install a new fan in the VFD. Assemble the VFD. Ensure that the air direction of the fan is
consistent with that of the VFD, as shown in the following figure.
Fan plug snap
Straight
screwdriver
1. Remove the fan cable through the straight
screwdriver.
Straight
screw driver
Fan cover snap
2. Remove the fan cover through the straight
screwdriver.
3. Take out of the fan and replace it.
Figure 8-1 Fan maintenance for 2.2–7.5kW VFD models (disassembly with tools)