EasyManuals Logo
Home>Lenze>Control Unit>ECS series

Lenze ECS series User Manual

Lenze ECS series
483 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #105 background imageLoading...
Page #105 background image
Commissioning
Carrying out basic settings with GDC
6
105
EDBCSXA064 EN 3.2
Detailed
information
Brief descriptionSettings
10. Set the polarity of the digital
inputs and outputs.
Select Terminal I/O Digital inputs/outputs in the GDC
parameter menu:
l C0114/x (polarity of dig. inputs X6/DI1 ... DI4)
l C0118/1 (polarity of dig. output X6/DO1)
129
11. Enter machine parameters. Set machine parameters as for instance maximum speed
and ramp times in the parameter menu under Short
setup Motor setting .
130
12. Switch on the mains. l Green LED is blinking and red LED is off:
Controller is ready for operation.
l Green LED is off and red LED is blinking:
An error has occurred. Eliminate the error before you
continue commissioning.
The basic settings are completed now.
Proceed as follows:
ƒ Enable controller ( 131).
ƒ Save parameters in the controller with C0003 = 1.
ƒ Save parameter set with GDC in the parameter set file.
ƒ Optimise drive behaviour ( 141).

Table of Contents

Other manuals for Lenze ECS series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze ECS series and is the answer not in the manual?

Lenze ECS series Specifications

General IconGeneral
BrandLenze
ModelECS series
CategoryControl Unit
LanguageEnglish

Related product manuals