Mechanical installation
Mounting with thermal separation (push−through technique)
4
51
EDBCSXA064 EN 3.2
4.3 Mounting with thermal separation (push−through technique)
For the push−through technique the rear panel of the control cabinet must be a steel plate
with a thickness of at least 2 mm.
The edges of the mounting cutout and the fixing holes for the clamps must be slightly
curved inwards (towards the axis module).
Cooling
With the separated heatsink the heat generation in the control cabinet can be reduced.
ƒ Distribution of the power loss:
approx. 65 % via separated cooler
approx. 35 % in the inside of the axis module
ƒ Protection class of the separated cooler: IP54
The sealing surface at the heatsink of the axis module must rest completely
against the mounting plate.
Use a liquid thread sealant to bond the screws of the clamps.
ƒ For sufficient cooling of the drive system:
Air flow behind the rear panel of the control cabinet must be ³ 3 m/s (e.g. by means
of a collective fan).
ƒ With sufficient cooling, the rated data of the axis modules remain valid.

Table of Contents

Other manuals for Lenze ECS series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze ECS series and is the answer not in the manual?

Lenze ECS series Specifications

General IconGeneral
BrandLenze
ModelECS series
CategoryControl Unit
LanguageEnglish

Related product manuals