Commissioning
Setting of the feedback system for position and speed control
TTL/SinCos encoder as position encoder and resolver as speed encoder
6
118
EDBCSXA064 EN 3.2
6.8.3 TTL/SinCos encoder as position encoder and resolver as speed encoder
A TTL incremental encoder connected to X8 or a SinCos encoder without serial
communication can be configured as a position encoder with a resolver connected to X7
being used as a speed encoder.
Observe the following setting sequence:
1. Select TTL/SinCos encoder as position encoder.
Incremental encoder (TTL encoder): C0490 = 1
SinCos encoder without serial communication: C0490 = 2
If X8 has been selected as output by changing C0491, X8 will be automatically reset to
input through the encoder selection.
2. Select resolver as speed encoder.
C0495 = 0
3. Select encoder used.
Incremental encoder (TTL encoder): C0419 = 110 ... 113
SinCos encoder without serial communication: C0419 = 210 ... 213
Encoder used is not in the list: C0419 = 1 ("Common")
4. When setting C0419 = 1 ("Common") configure encoder data.
Note!
When setting C0419 = 11x or 21x do not configure encoder data.
The encoder data (C0420, C0421, C0427) is set automatically in accordance
with the selection.
C0420 (number of increments of the encoder)
C0421 (encoder voltage)
C0427 (signal type of the encoder)
5. Save settings with C0003 = 1.

Table of Contents

Other manuals for Lenze ECS series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze ECS series and is the answer not in the manual?

Lenze ECS series Specifications

General IconGeneral
BrandLenze
ModelECS series
CategoryControl Unit
LanguageEnglish

Related product manuals