System modules
DCTRL_DriveControl (node number 121)
Display of digital status signals
13
327
EDBCSXA064 EN 3.2
13.15.8 Display of digital status signals
Via DCTRL_wStat, a status word is output, consisting of signals generated by the
SB DCTRL_DriveControl as well as of signals of freely configurable SB inputs.
The status word can be displayed via C0150.
STAT
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
C0150
DCTRL_DriveControl
DCTRL_bStateB2_bDCTRL_bStateB2_b
DCTRL_wStat
DCTRL_bStateB0_b
DCTRL_b _bStateB3
DCTRL_b _bStateB4
DCTRL_bStateB5_b
DCTRL_bStateB14_b
DCTRL_bStateB15_b
DCTRL_bNActEq0_b
DCTRL_bImp_b
DCTRL_bCInh_b
DCTRL_bStat1_b
DCTRL_bStat2_b
DCTRL_bStat4_b
DCTRL_bStat5_b
DCTRL_bWarn_b
DCTRL_bMess_b
ECSXA266
Fig. 13−21 Output of the status word "DCTRL_wStat"