System modules
AIF_IO_Management (node number 161)
Inputs_AIF_Management
13
255
EDBCSXA064 EN 3.2
13 System blocks
13.1 AIF_IO_Management (node number 161)
13.1.1 Inputs_AIF_Management
This SB serves to monitor the communication of a fieldbus module connected to the
automation interface (AIF).
ƒ In the event of an error, AIF_bCe0CommErr_b is set to TRUE and the communication
error "CE0" (LECOM no. 61) is set. The response to this can be configured via C0126
(default setting: off).
ƒ New AIF fielbus modules (e. g. 2133 and 2175) also use
AIF_bFieldBusStateBit0_b ... AIF_bFieldBusStateBit15_b to transfer an error number
from the fieldbus module.
ƒ C2121 serves to display the status.
Please read the documentation for the connected fieldbus module.
AIF
Communication
Error
AIF
Fieldbus State
X1
Inputs_AIF_Management
AIF_bCe0CommErr_b
AIF_bFieldBusStateBit0_b
AIF_bFieldBusStateBit1_b
AIF_bFieldBusStateBit2_b
AIF_bFieldBusStateBit6_b
AIF_bFieldBusStateBit5_b
AIF_bFieldBusStateBit4_b
AIF_bFieldBusStateBit3_b
AIF_bFieldBusStateBit7_b
AIF_bFieldBusStateBit8_b
AIF_bFieldBusStateBit9_b
AIF_bFieldBusStateBit10_b
AIF_bFieldBusStateBit14_b
AIF_bFieldBusStateBit13_b
AIF_bFieldBusStateBit12_b
AIF_bFieldBusStateBit11_b
AIF_bFieldBusStateBit15_b
ECSXA200
Fig. 13−1 System block "Inputs_AIF_Management"

Table of Contents

Other manuals for Lenze ECS series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze ECS series and is the answer not in the manual?

Lenze ECS series Specifications

General IconGeneral
BrandLenze
ModelECS series
CategoryControl Unit
LanguageEnglish

Related product manuals