Appendix
Memories
Temporary codes
14
380
EDBCSXA064 EN 3.2
E4 00 0A 00 01 00 00 00 1C FF 00 00
wSizeHeader = 00 E4 = 228 Bytehex
wDataType = 00 0A = 10 (Cam data)hex
dwVersion =00000001hex
dwRealSize = 00 00 FF 1C = 65308 Bytehex
ECSXA295
Fig. 14−1 Header interpretation
14.3.4 Temporary codes
The codes C2500 and C2501 are temporary codes, i. e. the data of these codes
ƒ does not assign storage space in the EPROM of the drive.
ƒ cannot be stored with C0003 = 1 in the parameter set of the drive.
ƒ is lost after switch−off of the drive or after mains failure.
ƒ is fixedly interlinked with the flag area of the PLC.
Tip!
ƒ Temporary codes are suited for the reception of parameters which are to be
accessed during a switch−on cycle of the ECSxA... axis module only.
ƒ Furthermore, the codes present the possibility to directly (e.g. via HMI)
access the flag area of the ECSxA... axis module without having to apply a
variable.
Code Possible settings IMPORTANT
No. Designation Lenze/
{Appl.}
Selection
C2500
PLC flag 1 ... 255
380
0 {1} 65535
C2501
PLC flag 256 ... 512
380
0 {1} 65535