System bus (CAN / CAN−AUX) configuration
Setting the boot−up time/cycle time
8
164
EDBCSXA064 EN 3.2
IMPORTANTPossible settingsCode
SelectionLenze/
{Appl.}
DesignationNo.
C2456 CAN time settings for CAN bus
interface X14 (CAN−AUX)
163
1 CANa times 3000 0 {1 ms} 65000 CAN−AUX boot−up time:
Delay time after mains
connection for initialisation
through the master.
2 CANa times 0
CANaux2...3_OUT cycle times:
Factor for the task time to send
process data telegram.
0 = event−controlled
transmission
3 CANa times 0
4 CANa times 20 Delay time for initial
transmission of the process data
objects 2 and 3 after the CAN bus
changed to "Operational"
Save changes with C0003 = 1.
The settings are only accepted after carrying out one of the following actions:
ƒ Renewed switch−on of the 24 V low−voltage supply
ƒ Reset node via the bus system (by the network management (NMT))
ƒ Variable CAN_bResetNode_b or CANaux_bResetNode_b = TRUE
ƒ Reset node with C0358/2458 = 1
Note!
If reset node is executed via GDC, communication will be interrupted. You
therefore have to log in again manually or find the devices connected to the
bus once again (fieldbus scan).

Table of Contents

Other manuals for Lenze ECS series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze ECS series and is the answer not in the manual?

Lenze ECS series Specifications

General IconGeneral
BrandLenze
ModelECS series
CategoryControl Unit
LanguageEnglish

Related product manuals