System modules
ANALOG1_IO (node number 11)
Inputs_ANALOG1 (analog input)
13
276
EDBCSXA064 EN 3.2
System variables
Variable Data
type
Signal
type
Address Display
code
Display
format
Comments
AIN1_nIn_a integer analog %IW11.0 C0400 dec [%] Analog input 1
AIN1_bError_b BOOL binary %IX11.1.0 ˘ ˘
Only when C0034 = 1:
TRUE, if ½I½ < 2 mA
Codes
Code Possible settings IMPORTANT
No. Designation Lenze/
{Appl.}
Selection
C0026 Offset for relative analog signals
(AIN)
275
347
1 FCODE(offset) 0,0 −199,99 {0.01 %} 199,99 FCODE_nC26_1_a
2 FCODE(offset) 0,0 FCODE_nC26_2_a
C0027 Gain for relative analog signals
(AIN)
275
347
1 FCODE(gain) 100,0 −199,99 {0.01 %} 199,99 FCODE_nC27_1_a
2 FCODE(gain) 100,0 FCODE_nC27_2_a
C0034 Mst current 0
Master voltage/master current
on analog input (AIN1_nIn_a)
275
0 −10 ... + 10 V Master voltage
1 +4 ... +20 mA
Master current
2 −20 ... +20 mA
C0400 DIS: AnalogIn
Signal at the analog input
Read only
−199.99 {0.01 %} 199.99
C0598 MONIT SD5 3
Fault response − master current
monitoring at X6 < 2 mA
"MastISourceDef"
275
0 TRIP
2 Warning
3 Off