Technical data
Rated data
3
43
EDBCSXA064 EN 3.2
Rated data Type
Axis module
ECSx032 ECSx048 ECSx064
Output power 400 V mains S
rated
[kVA] 8.3 11.2 13.2
Data for operation with upstream power supply module
on mains voltage
U
mains
[V] 400 480 400 480 400 480
DC−bus voltage V
DC−bus
[V] 15 ... 770
DC−bus current I
DC−bus
[A] 15.6 12.5 20.9 16.8 24.5 19.6
Rated output current at 4 kHz
(causes a heatsink temperature of 70°C at an ambient
temperature of 20°C)
I
r
[A] 12.7 10.2 17.0 13.6 20.0 16.0
Rated output current at 8 kHz (at an ambient
temperature of 20°C it causes a heatsink temperature
of 70°C)
1)
I
r
[A] 8.5 6.8 11.3 9.0 13.3 10.6
Max. output current
(acceleration current)
I
max
[A] 32.0 48.0 64.0
Continuous current at standstill
2)
(holding current at 90°C, 4 kHz)
I
0,eff
4
kHz
[A] 16.0 12.8 23.0 18.4 27.0 21.6
Short−time standstill current
(holding current at 90 °C, 4 kHz)
2)
I
0,eff
4
kHz
[A] 18.1 27.2 36.3
Short−time standstill current
(holding current at 70 °C, 4 kHz)
2)
I
0,eff
4
kHz
[A] 24.0 36.0 48.0
Short−time standstill current
(holding current at 70 °C, 8 kHz)
2)
I
0,eff
8
kHz
[A] 12.1 18.1 24.2
Power loss (operation with rated
current at 4 kHz / 8 kHz)
Total
P
loss
[W]
144.5 166.5 199.0
Inside the device 27.5 34.5 41.0
Heatsink 117.0 132.0 158.0
Max. output frequency f
out
[Hz] 600
Mass m [kg] approx. 2.4 approx. 3.3
1)
If the heatsink temperature reaches 70°C, the switching frequency automatically changes to 4 kHz.
2)
The indicated temperature is the measured heatsink temperature (C0061).
Application software:
S = Speed & Torque P = Posi & Shaft
M = Motion A = Application