Configure Switching
120
ProSAFE 10-Gigabit Smart Managed Switch XS728T and XS748T User Manual
The following table describes the nonconfigurable STP Status fields displayed on the page.
Configure CST Settings
Use the CST Configuration page to configure Common Spanning Tree (CST) and Internal
Spanning Tree on the switch.
 To configure CST settings:
1. Connect your computer to the same network as the switch.
You can use a WiFi or wired connection to connect your computer to the network, or
connect directly to a switch that is off-network using an Ethernet cable.
2. Launch a web browser.
3. In the address field of your web browser, enter the IP address of the switch.
If you do not know the IP address of the switch, see Change the Default IP Address of the
Switch on page 10.
The login window opens.
Table 24. STP Status
Field Description
Bridge Identifier The bridge identifier for the CST. It is made up using the bridge priority and
the base MAC address of the bridge.
Time Since Topology Change The time in day-hour-minute-second format since the topology of the CST
last changed.
Topology Change Count The number of times that the topology changed for the CST.
Topology Change The value of the topology change parameter for the switch indicating
whether a topology change is in progress on any port assigned to the CST.
Possible values are True and False.
Designated Root The bridge identifier of the root bridge. It is made up from the bridge priority
and the base MAC address of the bridge.
Root Path Cost Path cost to the designated root for the CST.
Root Port Port to access the designated root for the CST.
Max Age (Secs) The maximum age timer controls the maximum length of time in seconds
that passes before a bridge port saves its configuration BPDU information.
Forward Delay (Secs) The derived value of the Root Port Bridge Forward Delay parameter.
Hello Time (Secs) Minimum time in seconds between the transmission of configuration
BPDUs.
CST Regional Root Priority and base MAC address of the CST regional root.
CST Path Cost Path cost to the CST tree regional root.

Table of Contents

Other manuals for NETGEAR ProSafe XS728T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NETGEAR ProSafe XS728T and is the answer not in the manual?

NETGEAR ProSafe XS728T Specifications

General IconGeneral
BrandNETGEAR
ModelProSafe XS728T
CategorySwitch
LanguageEnglish

Related product manuals