EasyManuals Logo
Home>NETGEAR>Switch>ProSafe XS728T

NETGEAR ProSafe XS728T User Manual

NETGEAR ProSafe XS728T
373 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #93 background imageLoading...
Page #93 background image
Configure Switching
93
ProSAFE 10-Gigabit Smart Managed Switch XS728T and XS748T User Manual
5. Select Switching> LAG > Advanced > LACP Port Configuration.
6. Select one or more interfaces by taking one of the following actions:
• To configure a single interface, select the check box associated with the interface, or
type the interface number in the Go To Interface field and click the Go button.
• To configure multiple interfaces with the same settings, select the check box
associated with each interface.
• To configure all interfaces with the same settings, select the check box in the heading
row.
7. In the LACP Priority field, specify the LACP priority value for the selected interfaces.
This value specifies the device’s link aggregation priority relative to the devices at the
other ends of the links on which link aggregation is enabled. A higher value indicates a
lower priority. The range is 1 to 65535. The default value is 128.
8. In the Timeout field, configure the administrative LACP time-out value:
• Long. Specifies a long time-out value.
• Short. Specifies a short time-out value.
9. Click the Apply button.
The updated configuration is sent to the switch. Configuration changes take effect
immediately.
Configure VLANs
Adding virtual LAN (VLAN) support to a Layer 2 switch offers some of the benefits of both
bridging and routing. Like a bridge, a VLAN switch forwards traffic based on the Layer 2
header, which is fast, and like a router, it partitions the network into logical segments, which
provides better administration, security, and management of multicast traffic.
By default, all ports on the switch are in the same broadcast domain. VLANs electronically
separate ports on the same switch into separate broadcast domains so that broadcast
packets are not sent to all the ports on a single switch. When you use a VLAN, users can be
grouped by logical function instead of physical location.

Table of Contents

Other manuals for NETGEAR ProSafe XS728T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NETGEAR ProSafe XS728T and is the answer not in the manual?

NETGEAR ProSafe XS728T Specifications

General IconGeneral
BrandNETGEAR
ModelProSafe XS728T
CategorySwitch
LanguageEnglish

Related product manuals