4-5
Confidential
1.4 Initialize the EEPROM parameters (Maintenance mode 01)
Initialize the EEPROM parameters, referring to Chapter 5, Section 1.3.1.
1.5 Restore the head calibration data (Maintenance mode 68)
Restore head calibration data that has been backed up in an external memory,
referring to Chapter 5, Section 1.3.25.
If the restoration is successfully completed, the procedure given in Section 1.15 is not
required.
1.6 Set the serial number (Maintenance mode 80)
Set the serial number, referring to Chapter 5, Section 1.3.32.
The serial number can also be set with the service setting tool (BrUsbSn.exe) that
enables the head property information to be updated (Section 1.7) at the same time.
The serial number setting procedure is given below.
(1) Turn the machine on and switch it to the maintenance mode.
(2) Connect the machine to your PC using a USB cable.
(3) On the PC, run the service setting tool (BrUsbSn.exe) to display the following
window.
(4) In Product Category, select 1. Ink-Model.
(5) Select 2014 Model_2.