DVS Series Managed Industrial Ethernet Switches User’s Manual
LLDP Basic Settings
Description Factory Default
LLDP Status
Specify the status of STP on the switch:
Enable: LLDP is enabled. You can configure LLDP, and the settings
take effect after you have applied them.
Disable: LLDP is disabled. You can still configure LLDP, but the
settings do not take effect after you have applied them.
Enable
Transmit Interval (8 to 32768)
Enter the interval in seconds to transmit the LLDP frames. Enter a
number in the range of 5 to 32768 seconds.
30
Holdtime Multiplier
Enter the hold time multiplier in seconds. The hold time multiplier
multiplies the transmit interval to define the Time to Live (TTL) period.
Enter a number in the range of 2 to 10 seconds.
4
Reinitialization Delay
Enter the delay in seconds before reinitialization. Enter a number in the
range of 1 to 10 seconds. A longer time prevents frequent
reinitializations.
2
Notification Interval
Enter the interval in seconds for the transmission of notifications. Enter
a number in the range of 5 to 3600 seconds.
5
3.13.1.2 LLDP Interface Configuration
You can configure LLDP settings for an individual interface in this page.
Interface Settings
Description Factory Default
Port
This field displays the interface number.
interface number
3-116