Settings Related to Waiting Time
Waiting Time in Manual Feeding [Manual Feeding]
Configure the settings when manually loading and scanning one sheet at a time.
When you scan by manually loading one sheet at a time, you can specify the waiting time (interval) for loading the
next document in the ADF paper chute (feeder). This enables continuous scanning as long as you load a document
within the specified time.
If the specified time is exceeded, the scan is finished automatically.
1 Start up the Software Operation Panel.
For details, refer to Starting Up the Software Operation Panel (page 241).
2 From the list on the left, select [Device Setting 2] → [Manual Feeding].
3 Set [Timeout Time].
For [Timeout Time], specify the time period until which the scanner confirms that no documents are loaded
in the ADF paper chute (feeder) (the interval between the last scan and the detection of whether the next
document is loaded or not).
The factory default setting is "10 seconds".
● When scanning more than one document in succession manually
1. Select [Enable] for [Continuous Feed Mode].
2. Select the time for [Timeout Time].
Scanner Settings (Software Operation Panel)