2. While bracing the rack from the front, push in the tabs on both sides of
the front of the enclosure behind the front panel and pull the enclosure
forward. Then slide the enclosure out of the rack as far as the enclosure
goes.
3. Using the #2 Phillips screwdriver, unscrew and remove the silver self-
tapping screw in each of the four corners on the back of the front of the
enclosure.
4. Pull the front panel off the front of the enclosure.
5. Gently push the top of the light pipe assembly to the left and rock it to
the left to free the right side. Then push the light pipe assembly to the
right side and pull the left side out of the enclosure.
6. While pushing back the green plastic sliders at the front end of the rails
on both sides of the enclosure, push back on the enclosure to release it.
Then slide the enclosure all the way back into the rack until the
enclosure clicks into place.
7. Pack the front panel, light pipe assembly, and self-tapping screws in the
applicable box from the enclosure carton, with the screws in their
original packaging or in a bag that you supply.
Step 15 (conditional): Remove the cable management
arms
If the S10 Node was returned racked, you need to remove the cable
management arms. These arms are attached to both the enclosure and to
cable management arm extenders that are attached to the outer enclosure
rails. The arms most likely have the power cables threaded through them.
Chapter 3: Refurbishing an HCP S10 Node
47
HCP S Series Node Refurbishment
Step 15 (conditional): Remove the cable management arms